![operation spring cleaning in gwinnett county operation spring cleaning in gwinnett county](https://i.pinimg.com/236x/bc/7a/8b/bc7a8b8563802dcab46ff22a373bc336--delaware-prison.jpg)
Junctureof walls and floors shall be coved.26.5 The location of dressing rooms shall be arranged so thatbathers leaving a dressing room must pass the toilets and showers enroute to the swimming pool.26.6 Showers and lavatories shall be supplied with warm water at atemperature of 90 degrees to 110 degrees F from a single source. Hose bib with vacuum breaker required in each toilet room as a minimum.26.4 Toilet and shower room floors shall be constructed ofimpervious materials with no open cracks or joints, have an easilycleanable, non-slip finish and shall pitch toward a drain. Minimum of one (1) to be located in swimming pool area. 26.3 Shower, toilet and lavatory facilities shall be provided in accordance with the following schedule and shall be based on pool capacity computations set forth in Section 9.7027 herein, or on scheduled use periods as at schools: Fixture Males FemalesWater Closets 1/60 1/40Urinals 1/60 NALavatories 1/60 1/60Showers (minimum of 3 1/40 1/40each side)ĭrinking Fountain. 26.2 Dressing rooms, toilet rooms, shower rooms, shall be ventilated by natural or artificial means to effectively eliminate odors and condensation. Walls and partitions shall be of easily cleanable construction and junctions of walls and floors shall be coved. 25.3 Where bathhouses are used by both sexes at the same time, separate and clearly labeled dressing rooms separated by a tight partition shall be provided for each sex entrances and exits shall be screened to break the line of sight.Section 9-7026 Bathhouse Facilities (Public Pools) 26.1 Dressing room floors shall be easily cleanable, non-slip finish, impervious to moisture and sloped to drain.
![operation spring cleaning in gwinnett county operation spring cleaning in gwinnett county](https://media-beta.wsbtv.com/photo/2017/04/24/joel%20jackson%20sex%20sting_20170424153851694_7867905_ver1.0_640_360.jpg)
25.2 Bathhouses may also contain public areas, manager's area, first-aid room, and like areas. Comment - Consideration by the governing authority should be given to: distance to adjacent structures, bather load estimates, operator control, and health matters when evaluating bathhouse requirements for these potentially exempt establishments. The governing authority shall determine any bathhouse requirements for such establishments. 25.1 Bathhouse facilities may not be required for swimming pools located on premises of motels, hotels, or other transient residences, and apartment complexes where such facilities are available in adjacent structures and the swimming pool use is restricted to the employees, occupants, and guests of such establishments. Bathhouses shall be incompliance with Gwinnett County Building, Plumbing, Mechanical, Gas,and Electrical codes. Disposable cartridges shall be replaced when initial filtration rate is impaired by clogging.Section 9-7024 Make-up Water Facilities (Public Pools)Īll pools shall be equipped with provisions for adding make-up water tocompensate for water loss through evaporation and to waste so that aconstant water level is maintained while the pool is in operation toenable continuous flow into skimmers or overflow gutters.Section 9-7025 Bathhouses (Public Pools)Bathhouses containing dressing rooms, showers, toilets, and lavatoriesshall be required for public swimming pools. Two (2)sets of filter cartridges shall be provided to facilitate cleaning and drying of one set while the other is in operation. Filter(s) shall be equipped with at least influent and effluent pressure gauges with gauge cocks and an air-relief valve. 23.5 Cartridge filters shall be designed for filter rate to the swimming pool of not more than 0.33 gallons per minute per square foot of effective filter area.
![operation spring cleaning in gwinnett county operation spring cleaning in gwinnett county](https://media-beta.wsbtv.com/photo/2017/04/24/alisha%20gaggaturu%20sex%20sting_20170424154513260_7867927_ver1.0_640_360.jpg)
23.4 High rate sand filters shall be designed for a filter rate to the swimming pool of not more than 20 gallons per minute per square foot of filtering surface shall meet the standards set forth in items 23.1 and 23.2 herein. Provision shall be made for completely and rapidly draining the filter. Filters shall be equipped for cleaning by one or more of the following methods: back-washing, air-bump-assist backwashing, spray wash (mechanical or manual), or agitation. Filtering area, where fabric is used, shall be determined on the basis of effective filtering surfaces as created by the septum supports with no allowances for areas of impaired filtration, such as broad supports, folds, or portions which may bridge. 10%) and shall be capable of continually feeding within a calibrated range, adjustable from 2 to 6 ppm, at the design capacity of the recirculating pump.